| ||||||||||||||
|
|
|||||||||||||
Department of Anesthesia, Central Hospital, Herning, Denmark
Abstract
Nitrous oxide can diffuse into the cuff of an endotracheal tube during tracheal intubation, and the cuff pressure against the tracheal Wall may Cause mucosal damage. An endotracheal tube has been developed (Brandt Anesthesia Tube) that effectively limits nitrous oxide-related intracuff pressure increases. We determined whether the incidence of postoperative throat could be reduced by using this tube. Forty-eight female patients, 18–50 yr of age, were included in the study. Endotracheal intubation was performed with either a Brandt Anesthesia Tube or a Mallinckrodt endotracheal tube. All patients were interviewed postoperatively after 20–30 h by individuals who did not know which tube was used. In the Mallinckrodt group, 12 of 20 patients had a sore throat and patients had intracuff pressures greater than 25 mm Hg. Only 3 of 20 patients in the Brandt group had a sore throat. We found that the incidence of sore throats after intubation could be significantly reduced by using the Brandt Anesthesia Tube (P <0.005).
This article has been cited by other articles:
![]() |
L. Rose and L. Redl Survey of Cuff Management Practices in Intensive Care Units in Australia and New Zealand Am. J. Crit. Care., September 1, 2008; 17(5): 428 - 435. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A. Sumathi, T. Shenoy, M. Ambareesha, and H. M. Krishna Controlled comparison between betamethasone gel and lidocaine jelly applied over tracheal tube to reduce postoperative sore throat, cough, and hoarseness of voice Br. J. Anaesth., February 1, 2008; 100(2): 215 - 218. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Combes, L. Andriamifidy, E. Dufresne, P. Suen, S. Sauvat, E. Scherrer, P. Feiss, J. Marty, and P. Duvaldestin Comparison of two induction regimens using or not using muscle relaxant: impact on postoperative upper airway discomfort Br. J. Anaesth., August 1, 2007; 99(2): 276 - 281. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Itagaki, M. Kikura, and S. Sato Incidence and Risk Factors of Postoperative Vocal Cord Paralysis in 987 Patients After Cardiovascular Surgery Ann. Thorac. Surg., June 1, 2007; 83(6): 2147 - 2152. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Ogata, K. Minami, T. Horishita, M. Shiraishi, T. Okamoto, T. Terada, and T. Sata Gargling with Sodium Azulene Sulfonate Reduces the Postoperative Sore Throat After Intubation of the Trachea Anesth. Analg., July 1, 2005; 101(1): 290 - 293. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. D. Mac Murdo and C. W. Buffington Brand and Size Matter When Choosing a Syringe to Relieve Pressure in a Tracheal Tube Cuff Anesth. Analg., November 1, 2004; 99(5): 1445 - 1449. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Karasawa, A. Takita, T. Mori, I. Takamatsu, Y. Kawatani, and T. Oshima The BrandtTM Tube System Attenuates the Cuff Deflationary Phenomenon After Anesthesia with Nitrous Oxide Anesth. Analg., February 1, 2003; 96(2): 606 - 610. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Karasawa, T. Okuda, T. Mori, and T. Oshima Maintenance of stable cuff pressure in the BrandtTM tracheal tube during anaesthesia with nitrous oxide Br. J. Anaesth., August 1, 2002; 89(2): 271 - 276. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Karasawa, N. Matsuoka, M. Kodama, T. Okuda, T. Mori, and Y. Kawatani Repeated Deflation of a Gas-Barrier Cuff to Stabilize Cuff Pressure During Nitrous Oxide Anesthesia Anesth. Analg., July 1, 2002; 95(1): 243 - 248. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. G. Kadar, C. H. Ing, P. F. White, C. A. Wakefield, B. A. Kramer, and K. Clark Anesthesia for Electroconvulsive Therapy in Obese Patients Anesth. Analg., February 1, 2002; 94(2): 360 - 361. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Karasawa, T. Mori, T. Okuda, and T. Satoh Profile Soft-Seal Cuff, a New Endotracheal Tube, Effectively Inhibits an Increase in the Cuff Pressure Through High Compliance Rather than Low Diffusion of Nitrous Oxide Anesth. Analg., January 1, 2001; 92(1): 140 - 144. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Karasawa, T. Mori, Y. Kawatani, T. Ohshima, and T. Satoh Deflationary Phenomenon of the Nitrous Oxide-Filled Endotracheal Tube Cuff After Cessation of Nitrous Oxide Administration Anesth. Analg., January 1, 2001; 92(1): 145 - 148. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Karasawa, T. Ohshima, I. Takamatsu, T. Ehata, I. Fukuda, Y. Uchihashi, and T. Satoh The Effect on Intracuff Pressure of Various Nitrous Oxide Concentrations Used for Inflating an Endotracheal Tube Cuff Anesth. Analg., September 1, 2000; 91(3): 708 - 713. [Abstract] [Full Text] [PDF] |
||||
|